Multi Function Water Quality Meters
The new MM-60R Benchtop R Series Meter
with advanced features and exclusive sensor memory
Dual Channels for pH, ORP, Ion, Conductivity, Resistivity, Salinity, Concentration, Dissolved Oxygen, Saturation, and Temperature. (Plus Ambient temp. and humidity)
The MM-60R Benchtop Multi-Function Meter. Simply stated.."Awesome!"
The new R series meters are designed for high performance with easy operation. The MM-60R combines years of instrument development, exclusive sensor technology, along with unmatched performance to offer a multi-parameter, Multi channel, full function benchtop meter for an entire array of applications.
Features:
- The DKK-TOA exclusive calibration memory function. Intelligent Sensor "Calibration Memory" - The electrode stores 3 sets of calibration data in a microchip of the electrode including calibration date, sensor type, ID #, etc.. The information is downloaded to the pH meter when attached. Always a documented electrode with complete paper trail.
- GLP Compliant- Compatible with electronic recording and electronig signature regulations under 21 CFR Part 11.
- SOP Documentation guide available.
- On-board Help function at your fingertips
- USB and LAN-network interface connectivity
- Password protection and enhanced printing functions. User restricted access.
- Calibration data storage function (20 sets of data), including sensor ID, cal data, zero potential and slope. Sensor replacement function and alarm indications. Diagnostic messages are displayed when an error indication is found.
- Easy to read and use menu driven operation, back lit large LCD display.
- Up to a 5-point automatic pH calibration with automatic recognition of US standard, JIS Standard, or other buffers.
- Ambient temperature and humidity logging available.
- Data storage function- up to 300 sets of measured data can be stored in memory, each channel!.
- System expandability)- optional peripherals can be added such as turn tables (12,18, or 36 samples) and electrode selector (max 5 electrodes).
Also consider the individual R-series Conductivity Meters and the pH Meters
The MM-60R Multi-Function Meter
![]() |
MM-60R |
Main Unit
MM-60R |
Multifunction Meter w/Standard Accessories. |
Optional equipment and accessories for MM-60R
6949070K (HM-30R, CM-30R, MM-30R) |
Ambient Temperature and humidity sensor |
6949080K (HM-30R, CM-30R, MM-30R) |
Remote switch for auto hold, data memory, and print key |
EPS-R |
External printer unit w/cable, 60mm wide |
118B603 |
Connection cable to external printer |
P000119 |
60mm wide printer Paper, 20 roll/pk |
ORD00001 |
Ink Ribbon Cartridge for External Printer, 1 pc |
G-LOG2 |
Data Acquisition Software for PC to CSV format. (Requires 118B604 RS-232C cable, 2m) |
R-LOG |
USB/LAN data collection software for PC to CSV format. |
ES-1G (HM-30R, MM-60R) |
Electrode Selector for up to 5 pH, ORP, or Ion electrodes |
ES-1GC (CM-30R, MM-60R) |
Conductivity Cell Selector for up to 5 Cond. Cells |
ES-1GC (MM-60R) |
Electrode Selector for up to 5 DO electrodes |
AH-1G |
Automatic Electrode Calibration Unit |
AC-1V (HM-30R, CM-30R. MM-60R) |
Control Box allows for upper and lower pH limits to be controlled by 100 V relay for reagent pump/pH control.. |
OGC00002 |
RS-232 Conection Cable, 2m. |
PC-1G (HM-25R, HM-30R, MM-60R) |
pH Checker / Calibration unit |
EC-1G (CM-25R, CM-30R, MM-60R) |
Electrical Conductivity Check test plug. |
TC-1G (HM, CM, or MM R-series) |
Temperature Checker test plug. |
OIF00001 |
Electrode Stand Set |
OIB00001 |
Electrode Holder (Electrode Attachment Not included) |
OIB00004 - OIB00008 |
Electrode Attachment, G/04, J/05, Ion/06, DP/07, N/08 |
Stirrers assemblies: |
|
ST-15 |
Magnetic stirrer |
S-HLD-S |
Electrode Holder |
S-STD-S |
Electrode Stand |
ST-20A |
Overhead Rod type stirrer and electrode holder |
Automatic Samplers: |
|
TTT-510-12 |
Automatic turntable unit, 12 samples.(uses 200ml tall beakers) |
TTT-510-18 |
Automatic turntable unit, 18 samples.(uses 100ml tall beakers) |
TTT-510-32 |
Automatic turntable unit, 32 samples.(uses 50ml tall beakers) |
TTT-510-60 |
Automatic turntable unit, 60 samples.(uses 20ml tall beakers) |
OGC00001 |
G Series meter to TTT-510 Connection Cable, 1.5M(std) |
P000020 |
Waste Water Valve |
P000021 |
Waste Water Valve, electric magnetic |
P000022 |
Non-Aqueous pump for reagent delivery |
P000032 |
Propeller Stirrer motor |
Additional electode holders, connection cables, extensions, beakers, and accessories also available. |
pH Electrodes
GST-5741C (General Purpose) (Standard with HM-30R) |
Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml sample volume. Calibration Memory function |
ELP-031 (Organic Solvent) |
Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Moveable sleeve junction. Min. 3ml sample volume. Calibration Memory function |
ELP-032 (Precision pH)) |
Strong pH Glass Electrode, 0-14pH, 0-60C (3 in 1; pH, Ref, Temp.) Fixed sleeve junction. Min. 2ml sample volume. Calibration Memory function |
GST-5723S (Precision Trace Volume) |
pH Glass Electrode, 0-11pH, 0-60C (3 in 1; pH, Ref, Temp.) |
GST-5724C (Insertion/spear type, Neutralization) |
pH Glass Electrode, 0-12pH, 0-60C (3 in 1; pH, Ref, Temp.) |
ELP-035 (Trace sample volume) |
5mm Diam. Strong pH Glass Electrode, 0-13pH, 0-100C (3 in 1; pH, Ref, Temp.) 0.5ml sample volume. Calibration Memory function |
ELP-036 (Ultra trace Volume) |
3mm Diam. Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1; pH, Ref, Temp.) 0.3ml sample volume. Calibration Memory function |
ELP-037 (Test Tube use) |
8mm Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-100C (3 in 1; pH, Ref, Temp.) 0.5ml sample volume. Calibration Memory function |
ELP-038 (Ultra trace, narrow test tube use, NMR tube, etc.) |
3mm Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1; pH, Ref, Temp.) 0.3ml sample volume. Calibration Memory function |
GST-5720C (Flow Thru monitoring) |
pH Glass Electrode 0-12 pH, 0-60C (3 in 1; pH, Ref, Temp.) |
ELP-039 (Strong Alkali Use) |
pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) |
ELP-040 (Hydrofluoric Acid Use) |
pH Glass Electrode, 2-12pH, 0-50C (3 in 1; pH, Ref, Temp.) |
GST-5731C (General Purpose) |
Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml sample volume. |
PST-5721C (General Purpose ORP) (Reduction-Oxidation) |
ORP Electropde. 0-100C. 3 in 1 ORP Platinum Electrode, (mV, Ref, Temp.) 1ml samlpe volume. Calibration Memory function. |
Dissolved Oxygen Electrodes
OE-270AA Immersion / throw-in use |
DO: 0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00001 membrane set (High conc. use OCC00002). Cable Length: 3m standard. (5 and 11m available). |
OE-570BA |
DO: 0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00023 membrane set (High conc. use OCC00024). Cable Length: 3m standard. (5 and 11m available). |
OE-470BA |
DO: 0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00022 membrane set. Cable Length: 1m standard. Calibration memory function. |
OE-470AA |
DO: 0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00022 membrane set. Cable Length: 1m standard. Built in stirrer. Calibration memory function. |
Conductivity Cells
CT-57101B (General Purpose) Immersion type |
EC: 100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m, Min. 4ml sample volume. Diam 14mmx26mm. Built in temp. Calibration Memory function |
CT-57101C (Low Range Cond.) |
EC: 5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m, Min. 6ml sample volume. Diam 14mmx42mm. Built in temp. Calibration Memory function |
CT-57101A (High Range Cond.) |
EC: 1mS/m to 100S/m (10uS/cm to 1S/cm), 0-100C., Cell const. 1000E10-1m, Min. 39ml sample volume. Diam 36mmx38mm. Built in temp. Calibration Memory function |
CT-87101B (General Purpose) |
EC: 100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m, Cell volume is 4ml. Built in temp. Calibration Memory function |
CT-27111D (Pure Water Use) |
EC: 5uS/m to 20S/m (0.05uS/cm to 200ms/cm), 0-80C., Cell const. 1E10-1m, Cell volume is 8ml. Built in temp. Calibration Memory function. Note: a seperate flow cell is required. CEF-22A (PP), or CEF-23A (SUS316) |
CT-87101C (Low Range Cond.) |
EC: 5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m, Cell volume is15ml. Built in temp. Calibration Memory function |
CT-87102A (High Range Cond.) |
EC: 10mS/m to 100S/m (100uS/cm to 1ms/cm), 0-100C., Cell const. 2000E10-1m, Cell volume is 1ml. Built in temp. Calibration Memory function. Note: a rubber syringe septum or pump tube is required. |
Specific Ion Electrodes:
Electrode |
Measuring Range |
pH range/temp |
Influence of co-existent ions (selective coefficient) |
Ion Tip replacement |
Membrane |
Sodium ion, combination |
2.3 - 23K mg/l Na+ |
10-11 pH / 60C |
Mg+2, Ca+2, NH4+, Li+, K+=10E3 |
NA-100B |
Glass membrane |
Potassium ion, combination |
0.39 - 39K mg/l k+ |
5-6 pH / 50C |
H+=10E2, NH4+=3x10E2, Na+=2x10E3, Li=10E4 |
K-300B |
Liquid Membrane |
Calcium ion, combination |
0.4 - 40K mg/l Ca+2 |
5-6 pH / 50C |
Pb+2=33, Zn+2=45, Mn+2=1.7x10E2, Cd+2=8.8x10E2, Fe+2=1.2x10E3, Mg+2=1.8x10E3, Ba+2=1.9x10E3, Cu+2=2.7x10E3, Ni+2=9.0x10E3 |
CA-300 |
Liquid Membrane |
Fluoride ion, combination |
0.019 - 19K mg/l F- |
5-6 pH / 50C |
OH-=10E1, HPO4-2, HCO3-=10E3(pH7-8), Cl-, Br-, I-, NO3-, SO4-2,S2O3-2=10E5 |
F-200 |
Solid Membrane |
Chloride ion, combination |
1 - 35K mg/l Cl- |
5-6 pH / 50C |
S-2 must be absent, CN-, I-=10E5, Br-, S2SO3-2+10E-2, F-,NO3-, SO4-2, CO3-2, PO4-3=10E3 |
CL-200B |
Solid Membrane |
Cyanide ion, combination |
0.003 - 26 mg/l CN- |
12-13 pH / 50C |
S-2 must be absent, I-=10E-1, S2O3-2=10E1, Br-=10E3, NO3-, SO4-2, PO4-3=10E4, CO3-2, Cl, F-=10E5(at 10 mol/l) |
CN-200B |
Solid Membrane |
Nitrate ion, combination |
0.62 -62K mg/l NO3- |
5-6 pH / 50C |
I-=7x10E-2, Br-=1.7, NO2-=4.5, Cl-=2x10, CH3COO=1.2x10E2, SO4-2, CO3-2=1.7x10E2, F-=2x10E2 |
N-300 |
Liquid Membrane |
Bromide ion, combination |
0.8 - 80K mg/l Br- |
5-6 pH / 50C |
S-2 must be absent, CN-,I-=10E-4, S2SO3-2, SCN-=10E0, Cl=10E2, NO3-, SO4-2, CO3-2, F-=10E4 |
BR-200 |
Solid Membrane |
Iodide ion, combination |
0.01 - 127K mg/l I- |
5-6 pH / 50C |
S-2 must be absent, CN-=10E0, S2SO3-2=10E1, SCN-=10E3, Br=104, NO3, CO3-2, PO4-3, Cl-, F-=10E5 |
I-200 |
Solid Membrane |
Cadmium ion, combination |
0.01 - 1120 mg/l Cd+2 |
5-6 pH / 50C |
Hg+2, Ag+2, CU+2 must be absent, Pb+2, Fe+3=10E0, CR+3=10E2, Na+, K+, Mg+2, CA+2, Zn+2, Al+3=10E5 |
CD-200 |
Solid Membrane |
Copper ion, combination |
0.06 to 630 mg/l Cu+2 |
5-6 pH / 50C |
Hg+2, Ag+2 must be absent, Fe+3=10E-1, Al+3=10E1, CR+3=10E2, Na+, K+, Mg+2, CA+2, Zn+2, Al+3=10E5 |
CU-200 |
Solid Membrane |
Silver ion, combination |
0.1 to 108K mg/l Ag+ |
5-6 pH / 50C |
Hg+2 must be absent, Mg+2=10E3, CA+2, CU+2, Pb+2, Cd+2, Zn+2=10E4, Na+, K+=10E6 |
AG-200 |
Solid Membrane |
Sulfide ion, combination |
0.3 - 32K mg/l S-2 |
>13 pH |
--- |
S-200 |
Solid Membrane |
Ammonium Electrode (membrane type) AE-2041 |
0.09 - 1800 mg/l NH4+ |
>12 pH / 50C |
volatile amines |
AE-Film |
AE-2041 (Set of 10) |
Carbon Dioxide (membrane type) CE-2041 |
Dissolved gas: |
- / 50C |
Dissolved gas: volatile weak acid |
CTC-211 Diaphragm cartridge |
CE-2041 (set of 4) |
Notes on ion electrodes:: Selective coefficient: 10Ex denoted that a concentration of interfering ion in the sample soluton, that is greater than that of measured ion will give the same meter indication.
When coexisting ions are at a concentration that will affect the measurement value, solution pretreatment will be required to prevent or minimize interference.
The Combined ion electrodes are not designed as water proof sensors and are not built with temperature probes included.